METROPOL CABIN TECHNICAL SPECIFICATIONS
PRODUCTION DIMENSIONSCan Be Specially Produced On Demand.
HEIGHT2800 mm Parapet Included.
METAL MATERIALSST 37
BETOPANTSE 634-2
GLASS WOOLTS 901
POLYSTREN FOAMTS EN 13163
TECHNICAL DATA
EARTHQUAKE CONDITIONS1st degree
CLIMATE CONDITIONS3. Climate Zone
SNOW LOAD80 Kg/m²
WIND SPEED80 Km/Hour (provided that it is fixed to the ground)
EXTERNAL WALL TRANSMISSION COEFFICIENTK: 0.50 Kcal/m2hc
ROOF TRANSMISSION COEFFICIENTK: 0.69 Kcal/m2hc
BASE HEAT CONDUCTION COEFFICIENTK: 0.68 Kcal/m2hc
CHASSIS LOAD CAPACITY200 Kg/m²
BASE
FLOOR COATINGPVC Mineflo with 2 mm thickness is used as floor covering on 14 mm non-flammable Betopan boards as the floor covering.
OUTER WALL
SYSTEMIt is made with carcass with the help of specially shaped profiles.
EXTERIOR COATINGThe outer surface coating is optionally covered with 12 mm thick Taşonit or wood patterned concrete boards.
INTERNAL SURFACE COATINGThe inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC).
WALL INSULATION40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials.
INNER WALL
SYSTEMIt is made with carcass with the help of specially shaped profiles.
INTERNAL SURFACE COATINGThe inner surface coating is 8 mm thick betopan (inner surface coating PVC paneling is used in metropolitan cabins with WC).
WALL INSULATION40 mm thick, 10 kg/m³ polystyrene foam (EPS) with fire class E; It is made with heat-insulated complete, healthy and safe materials.
ROOF
ROOF SYSTEMIt is produced with the help of specially shaped construction and carrier one-piece profiles, and it is made with 20 cm eaves and 36 cm high parapet. Rain water is discharged through corner columns.
ROOF INSULATIONThe 80 mm thick mattress is made of glass wool (14 kg/m³).
INTERNAL SURFACE COATINGInner surface ceiling covering PVC paneling is used (optional 8 mm concrete board can be used (inner surface ceiling covering PVC paneling is used in metropolitan cabins with WC).
EXTERIOR COATING0.50 mm thick 27 mm *200 mm deep Natural Trapezoidal Galvanized Sheet
DOORS
EXTERIOR DOORIt is TSE certified white PVC joinery measuring 90*210 cm.
INTERIOR DOORIt is an American wooden door measuring 80*200 cm.
WINDOWS
WINDOWIt is TSE certified white PVC joinery in 120 * 100 cm dimensions.
SILLPVC moldings are used on the inner edges of the windows.
PINE4+9+4 double glazing is used.
DYES
EXTERIORExterior surfaces are painted in the desired color with silicone-based exterior paint.
DOOR CASES1 coat Rapid primer painted.
METAL PARTS1 coat of Rapid primer paint is applied.
ELECTRICAL INSTALLATION (Flush mounted)
SYSTEMEach room has a switch, a socket, and a telephone socket. In addition, spot luminaires are used for lighting at the four corners of the eaves.
CABLEElectrical power is 2000 W 220 Volts, 3x2.5 mm for sockets, 2x1.5 mm for lighting, TSE certified NYM cables are used.
LIGHTING FIXTURESTSE certified torus luminaire is used for lighting.
SOCKETS AND SWITCHESTSE certified materials are used.
SANITARY INSTALLATION
SANITARY WARE TSE certified materials are used.
CLEAN WATER INSTALLATIONTSE certified PPRC materials are used.
WASTE WATER INSTALLATIONTSE certified PVC material is used.
EXTERNAL LINKS
It is the customer's responsibility to pour concrete 20 cm more than the cabin dimensions, install the cabin on the ground, and make electricity, clean water and waste water connections.
LIFTING FUNCTION
Containers can be lifted and lowered from four corners with lifting eyebolts and steel ropes.